Series 3000 Commercial Single-Hung Windows

The Boyd Series 3000 is a top-of-the-line commercial aluminum single-hung window engineered for intense weather conditions and demanding coastal applications. A fixed upper sash and vertically operating lower sash provide traditional single-hung appearance and controlled ventilation, making the Series 3000 an excellent choice for public schools, universities, hospitals, government offices, military facilities, and other commercial or institutional buildings.

Tested to AW-PG75, the Series 3000 features a 4" thermal-break main frame, glazing up to 1.25" thick, true divided-lite and simulated muntin options, internal blinds or dual glazing, and a side-loaded operating sash that can be removed from the interior for maintenance and cleaning. An optional integral Water Management Fin System, screens, coordinated perimeter accessories, finish selections, and project-specific customization support challenging new-construction and replacement conditions. Selected impact-rated and blast-resistant configurations are available where the exact unit size, glazing, anchorage, installation method, and current documentation support the project requirements.

Series 3000 Product Details

Key commercial single-hung window attributes for product review:

Product AttributeSeries 3000
Window typeCommercial aluminum single-hung window
OperationFixed upper sash with vertically operating lower sash
Primary applicationsCoastal, institutional, education, healthcare, government, military, and other demanding commercial projects
Thermal barrierIntegral urethane thermal barrier
Main frame depth4"
Aluminum wall thicknessNominal .080" minimum at main-frame and sash members; nominal .125" minimum at the main-frame sill
Operating sashSide-loaded and removable from the interior for cleaning and maintenance without deglazing
Sash balancesUltra-Lift Class 5 balances selected for the operating-sash weight
Sash liftContinuous integral lift bar at the lower operating-sash rail
Locking hardwareSweep lock with mounted keeper at the operating-sash meeting rail
WeatherstrippingMultiple rows at the vertical sash rails, meeting rail, lock rail, and bottom sash rail
Maximum glazing thickness1.25"
Glazing methodFixed and operating sash are interior glazed with snap-in aluminum stops
Performance classAW-PG75
Testing standardAAMA/WDMA/CSA 101/I.S.2/A440-08
Air infiltration0.21 cfm/ft of sash crack at 6.24 psf
Water resistanceNo uncontrolled leakage at 12 psf
Structural performance112.5 psf
Condensation resistance factor53
Thermal performanceConfirm the current U-value with Boyd using the selected glazing and current project documentation
Muntin optionsTrue divided-lite, interior roll-form, and applied historical or simulated muntins; applied systems permit reglazing without removing the applied muntins
Blinds / dual glazingAvailable; internal blinds can be installed in a removable interior frame
ScreensAvailable for the operating sash
Water-management optionOptional integral Water Management Fin System
Forced-entry resistanceASTM F588, Performance Level 10
Impact capabilityImpact-rated configurations available; approval and documentation are configuration-specific.
Blast capabilityBlast-resistant configurations available; documentation is configuration-specific.

Series 3000 Product Data and Downloads

Use the current Boyd resource links below for Series 3000 detail drawings, guide specifications, accessories, impact and blast review, gallery images, and finish options.

ResourceAvailable Files
Series 3000 Detail DrawingsPDF | DWG
Series 3000 Guide SpecificationsDOC | PDF
Window AccessoriesPDF | View accessories
Impact and Florida Product Approval ReviewView impact systems
Blast-Resistant Configuration ReviewView blast systems
Series 3000 GalleryView gallery
Boyd Finish OptionsView finishes
Request a Bid / Project Help Get Direct Assistance™

When to Use the Series 3000 Single-Hung Window

  • Coastal or demanding commercial openings requiring a top-of-the-line single-hung aluminum window.

  • Public schools, universities, hospitals, government offices, military facilities, and other institutional applications.

  • Projects requiring AW-PG75 performance, a 4" thermally broken frame, 12 psf water resistance, and glazing up to 1.25" thick.

  • Traditional single-hung elevations requiring a fixed upper sash, vertically operating lower sash, and interior access for sash removal and cleaning.

  • Openings requiring true divided-lite, interior, or historical muntins, internal blinds, dual glazing, screens, or an optional integral Water Management Fin System.

  • Selected impact-rated or blast-resistant applications where the exact Series 3000 configuration and current supporting documentation match the project requirements.

Choosing a Boyd Single-Hung, Double-Hung, or Fixed Window

You are viewing the Series 3000 high-performance single-hung window. Review the related Boyd options below when the project requires double-hung operation, a different single-hung performance class, a shallower replacement frame, or matching fixed lights.

SeriesReview This Series For
Series 3500 Double-HungCoastal and demanding applications requiring two operating sash, AW-PG85 performance, a 4" frame, glazing up to 1.25", and selected impact or blast configurations.
Series 810 Single-HungHeavy-duty H-HC50 single-hung applications with a 4" frame, interior muntins, custodial access, and historic-replica coordination.
Series 800 Single-HungCW-PG50 heavy-commercial single-hung applications with a 4" frame and historic-replacement or institutional use.
Series 300 Single-HungA cost-competitive 2.375" thermally broken single-hung window for new construction, retrofit, hotels, motels, nursing homes, and apartments.
Series 4000 FixedMatching non-operable openings requiring a 4" thermal-break frame, glazing up to 1.25", and coordinated coastal, impact, or blast review.

Series 3000 Single-Hung Window Advantages

  • Top-of-the-line single-hung construction engineered for intense weather and coastal building conditions.

  • AW-PG75 performance with 12 psf water resistance and 112.5 psf structural performance.

  • A 4" thermal-break frame and interior bead glazing accommodate glass up to 1.25" thick.

  • Side-loaded operating sash can be removed from the interior for maintenance and cleaning without deglazing.

  • Block-and-tackle or Ultra-Lift Class 5 balances and an integral lift bar support dependable lower-sash operation.

  • True divided-lite, interior roll-form, and applied muntin options support contemporary, traditional, and historic-replica elevations.

  • Internal blinds, dual glazing, screens, and the optional integral Water Management Fin System expand project flexibility.

  • Panning, receptors, subsills, mullions, trims, nailing fins, leg extenders, finishes, and customization options support complex opening conditions.

  • Selected impact-rated and blast-resistant configurations are available, with final applicability matched to the exact assembly and current documentation.

Common Series 3000 Coordination Items

  • Single-hung operation: Confirm fixed upper sash, operating lower sash, lift and lock locations, operating force, balance selection, user access, and any custodial-control requirements.

  • Egress and clear opening: Where emergency escape or rescue requirements apply, provide the required net clear opening, minimum clear dimensions, sill height, unit size, and authority-having-jurisdiction comments.

  • Coastal and water management: Coordinate exposure, design pressure, water resistance, drainage, sill conditions, perimeter sealants, flashing, subsills, and whether the integral Water Management Fin System is required.

  • Glazing and blinds: Confirm complete glass makeup, overall thickness, safety glazing, interior bead-glazing access, dual glazing, internal blinds, controls, coatings, spacers, and project thermal criteria.

  • Muntins and appearance: Coordinate true divided-lite, interior roll-form, or applied historical muntins, grid pattern, profile, finish, reglazing requirements, and reviewing-authority comments.

  • Impact requirements: Match the exact Series 3000 configuration, glazing, opening size, positive and negative design pressures, anchors, substrates, and installation method to the applicable approval or project documentation.

  • Blast requirements: Provide the required protection level, threat criteria, glazing, opening size, anchorage, substrate, receptor, mullion, installation condition, and current documentation requirements.

  • Sash removal and screens: Preserve interior access for sash take-out, cleaning, balance or lock service, screen removal, blind maintenance, and glazing replacement.

  • Openings and accessories: Verify field dimensions, rough openings, substrates, anchors, panning, receptors, subsills, mullions, trims, nailing fins, leg extenders, sealants, drainage, and surrounding construction before release.

What to Send Boyd for a Series 3000 Review

Send as much of the following project information as available:

  • Project name, location, building type, bid date, construction schedule, architectural drawings, elevations, window schedules, specifications, and opening sizes.

  • Required single-hung operation, operating-sash sizes, lift and lock locations, balance or custodial-control needs, screens, and maintenance-access requirements.

  • Any egress or emergency-escape requirements, net clear opening targets, minimum clear dimensions, sill-height limits, and authority-having-jurisdiction comments.

  • Glazing makeup, overall thickness, coatings, spacers, safety glazing, internal blinds, dual glazing, muntin or grid pattern, historic-review requirements, and finish.

  • Required air, water, structural, thermal, forced-entry, impact, blast, coastal-exposure, approval, security, and jurisdictional criteria.

  • Water Management Fin System, panning, receptor, subsill, mullion, trim, nailing-fin, leg-extender, anchor, sealant, drainage, substrate, installation, and submittal requirements.

Related Hung, Coastal, Impact, and Blast Resources

Request a Bid / Project Help Get Direct Assistance
Series
3000
Window Type
Single Hung
Thermal Barrier
Yes
System Depth (Inches)
4.000
AAMA Rating
AW-PG75
Testing Standards Method
2008
Air Infiltration (CFM/FT)
.21@6.24
Water Resistance (PSF)
12.00
Structural Performance (PSF)
112.5
Maximum Glazing Thickness
1.25
CRF
53
U-Value
0.55
True Muntins
Yes
Interior Muntins
Yes
Historical Muntins
Yes
Blinds/Dual Glazing
Yes
Impact
Yes
Blast
Yes
3000 (SH) Series Gallery Here
3000 Series Detail Drawings PDF DWG
3000 Series Specifications DOC PDF
3000 Series Blast Detail Drawings PDF DWG
3000 Series Blast Specifications DOC PDF
Accessories PDF DWG
Finish Options Finishes
Order a Sample Request Here