Series 4000 Fixed Glass Windows

The Boyd Series 4000 is a commercial aluminum fixed glass window designed to provide a uniform appearance when coordinated with Boyd operable window systems. This high-performance fixed-window system supports contemporary architectural designs in coastal conditions and is well suited for universities, schools, hospitals, military structures, government buildings, and other commercial or institutional applications.

Tested to AAMA impact standards, the Series 4000 combines bead-glazed 1.25" insulated glass, a 4" main frame depth, thermal-break construction, and an AW-PG100 AAMA rating. Impact and blast documentation is configuration-specific, so the selected window, glazing, opening size, installation method, and project requirements should be reviewed against the applicable product information.

Series 4000 Product Details

Key fixed-window attributes for product review:

Product AttributeSeries 4000
Window typeCommercial aluminum fixed glass window
Design coordinationDesigned to provide a uniform appearance with Boyd operable window systems
Thermal barrierYes
Main frame depth4"
Maximum glazing thickness1.25"
Performance classAW-PG100
Air infiltration0.03 cfm/ft at 6.24 psf
Water resistance15 psf
Structural performance150 psf
Condensation resistance factor58
Muntin optionsTrue muntins and interior muntins
Impact capabilityImpact-rated configurations available; approval and documentation are configuration-specific.
Blast capabilityBlast-resistant configurations available; documentation is configuration-specific.

Series 4000 Product Data and Downloads

Use the current Boyd resource links below for Series 4000 detail drawings, guide specifications, accessories, impact and blast review, gallery images, and finish options.

ResourceAvailable Files
Series 4000 Detail DrawingsPDF  |  DWG
Series 4000 Guide SpecificationsDOC  |  PDF
Window AccessoriesPDF
Impact and Florida Product Approval ReviewView impact systems
Blast-Resistant Configuration ReviewView blast systems
Series 4000 GalleryView gallery
Boyd Finish OptionsView finishes
Request a Bid / Project Help Get Direct Assistance™

When to Use the Series 4000 Fixed Window

  • Fixed, non-operable openings that must coordinate visually with Boyd operable window systems.

  • Contemporary commercial and institutional projects in coastal conditions.

  • Universities, schools, hospitals, military structures, government buildings, and other high-performance applications.

  • Projects requiring AW-PG100 fixed-window performance, thermal-break construction, and glazing up to 1.25" thick.

  • Openings requiring impact-rated or blast-resistant configurations where the exact product documentation is reviewed for the project.

Choosing a Fixed, Double-Hung, or Single-Hung Window

You are viewing the Series 4000 fixed configuration. Review the related Series 3500 double-hung or Series 3000 single-hung systems when the project requires an operable hung window with coordinated commercial aluminum window performance.

SeriesReview This Configuration For
Series 3500 Double-HungOperable double-hung window openings with both an upper and lower operating sash.
Series 3000 Single-HungOperable single-hung window openings with a fixed upper sash and an operating lower sash.

Series 4000 Fixed Window Advantages

  • Provides a uniform appearance when coordinated with Boyd operable window systems.

  • Tested to AAMA impact standards for demanding contemporary and coastal applications.

  • Bead-glazed 1.25" insulated glass with a 4" main frame depth.

  • AW-PG100 performance with thermal-break construction.

  • True and interior muntin options for project-specific divided-lite requirements.

  • Impact-rated and blast-resistant configurations available; documentation is configuration-specific.

Common Series 4000 Coordination Items

  • Fixed and operable window coordination: Confirm sightlines, frame depth, finish, glazing, mullions, and visual alignment with adjacent projected, casement, hung, or other operable units.

  • Impact requirements: Match the exact Series 4000 configuration, glazing, opening size, design pressure, anchors, substrates, and installation method to the applicable approval or project documentation.

  • Blast requirements: Provide the project-specific explosive-load criteria and request documentation for the selected configuration.

  • Glazing: Confirm the specified insulated-glass makeup, overall thickness, safety-glazing requirements, and relationship to muntins or adjacent systems.

  • Coastal exposure and finish: Coordinate finish specifications, corrosion-related project requirements, adjacent metals, and maintenance expectations separately from impact or structural performance.

  • Openings and perimeter conditions: Confirm rough openings, field conditions, substrates, anchors, panning, receptors, mullions, trims, and surrounding construction before release.

What to Send Boyd for a Series 4000 Review

Send as much of the following project information as available:

  • Project name, location, bid date, and construction schedule.

  • Architectural drawings, elevations, window schedules, opening sizes, and specifications.

  • Required relationship between Series 4000 fixed windows and adjacent operable window systems.

  • Glazing makeup, finish, muntin, panning, receptor, mullion, trim, anchor, substrate, and installation requirements.

  • Applicable air, water, structural, thermal, impact, blast, coastal-exposure, approval, and jurisdictional requirements.

Related Fixed, Impact, and Operable Window Resources

Request a Bid / Project Help Get Direct Assistance™
Series
4000
Window Type
Fixed
Thermal Barrier
Yes
System Depth (Inches)
4.000
AAMA Rating
AW-PG100
Testing Standards Method
2008
Air Infiltration (CFM/FT)
.03@6.24
Water Resistance (PSF)
15.00
Structural Performance (PSF)
150.00
Maximum Glazing Thickness
1.25
CRF
58
U-Value
0.44
True Muntins
Yes
Interior Muntins
Yes
Historical Muntins
No
Blinds/Dual Glazing
No
Impact
Yes
Blast
Yes
4000 Series Gallery Here
4000 Series Detail Drawings PDF DWG
4000 Series Specifications DOC PDF
4000 Series Blast Specifications DOC PDF
4000 Series Blast Detail Drawings PDF DWG
Accessories PDF DWG
Finish Options Finishes
Order a Sample Request Here