Series 2200 NSL Narrow-Sightline Fixed Windows

The Boyd Series 2200 NSL is a commercial aluminum narrow-sightline fixed window for new construction and fixed-window replacement in contemporary building projects. Its slimmer visual profile gives architects and project teams a refined fixed-window option while maintaining the proven reliability and high-performance construction of the Series 2200 family.

The Series 2200 NSL is AAMA tested to AW-PG100 and features a thermal barrier, a 2.375" main frame depth, and bead-glazed insulated glass up to 1.5" thick. This versatile fixed-window system is well suited for schools, hospitals, universities, military offices, government buildings, and other commercial or institutional applications, and it is also available without narrow sightlines.

Series 2200 NSL Product Details

Key narrow-sightline fixed-window attributes for product review:

Product AttributeSeries 2200 NSL
Window typeCommercial aluminum narrow-sightline fixed window
Primary applicationsNew construction and fixed-window replacement
SightlineNarrow-sightline configuration
Thermal barrierYes
Main frame depth2.375"
Maximum glazing thickness1.5"
Glazing methodBead-glazed insulated glass
Performance classAW-PG100
Air infiltration0.01 cfm/ft² at 6.2 psf
Water resistance15 psf
Structural performance150 psf
U-value0.39
Muntin optionsTrue, interior, and historical muntins
Blinds / dual glazingAvailable
Impact capabilityNot identified as available in the current Series 2200 NSL product data
Blast capabilityNot identified as available in the current Series 2200 NSL product data

Series 2200 NSL Product Data and Downloads

Use the current Boyd resource links below for Series 2200 NSL detail drawings, guide specifications, accessories, gallery images, and finish options.

ResourceAvailable Files
Series 2200 NSL Detail DrawingsPDF  |  DWG
Series 2200 NSL Guide SpecificationsDOC  |  PDF
Window AccessoriesPDF  |  View accessories
Series 2200 NSL GalleryView gallery
Boyd Finish OptionsView finishes
Request a Bid / Project Help Get Direct Assistance™

When to Use the Series 2200 NSL Fixed Window

  • Fixed, non-operable openings where a narrow aluminum sightline is a primary architectural requirement.

  • New construction, renovation, and commercial window-replacement projects with contemporary elevations.

  • Schools, hospitals, universities, military offices, government buildings, and other institutional applications.

  • Projects requiring AW-PG100 fixed-window performance, thermal barrier protection, and glazing up to 1.5" thick.

  • Openings requiring true, interior, or historical muntins, internal blinds, dual glazing, or coordinated divided-lite designs.

Choosing a Standard, Narrow-Sightline, or Operable Window

You are viewing the narrow-sightline Series 2200 fixed configuration. Review the related standard fixed, narrow-sightline projected, and casement systems below when the project requires a different visible profile or an operable window with coordinated 2.375" framing and glazing options.

SeriesReview This Configuration For
Series 2200 FixedFixed, non-operable openings that do not require the narrow-sightline configuration.
Series 2300 NSL Projection
Project-In
Project-Out 
Operable projected-window openings requiring narrow sightlines and coordinated 2.375" framing.

Series 2200 NSL Fixed Window Advantages

  • Narrow sightlines create a refined contemporary appearance for fixed-window openings.

  • Proven, dependable fixed-window design for new construction and replacement projects.

  • Time-tested AW-PG100 performance with thermal barrier protection.

  • Bead-glazed insulated glass up to 1.5" thick with a 2.375" main frame depth.

  • True, interior, and historical muntins, plus blinds or dual-glazing options.

  • Also available as the standard Series 2200 fixed window without narrow sightlines.

Common Series 2200 NSL Coordination Items

  • Standard or narrow sightlines: Confirm the required visible profile and whether the project should use the standard Series 2200 or Series 2200 NSL configuration before finalizing elevations.

  • Replacement openings: Verify existing opening dimensions, frame exposure, perimeter conditions, panning, receptors, and the relationship between the narrower sightline and surrounding construction.

  • Fixed and operable coordination: Coordinate sightlines, frame depth, glazing, muntins, finish, and visual alignment with adjacent Series 2300 NSL projected or Series 2400 casement windows.

  • Glazing and divided lites: Confirm glass makeup, overall thickness, true or simulated muntins, internal blinds, dual glazing, and replacement-glazing requirements.

  • Performance requirements: Include the project specifications and applicable thermal, structural, air, water, and jurisdictional requirements.

What to Send Boyd for a Series 2200 NSL Review

Send as much of the following project information as available:

  • Project name, location, bid date, and construction schedule.

  • Architectural drawings, elevations, window schedules, opening sizes, and specifications.

  • Required narrow sightlines, exposed frame dimensions, replacement-opening conditions, and fixed-to-operable coordination requirements.

  • Glazing makeup, muntins, blinds, dual glazing, finish, panning, receptors, mullions, trims, anchors, and perimeter conditions.

  • Applicable air, water, structural, thermal, historic-detailing, and jurisdictional requirements.

Related Fixed Window and Project Resources

Request a Bid / Project Help Get Direct Assistance™
Series
2200 NSL
Window Type
Fixed
Thermal Barrier
Yes
System Depth (Inches)
2.375
AAMA Rating
AW-PG100
Testing Standards Method
2008
Air Infiltration (CFM/FT)
.01@6.24
Water Resistance (PSF)
15.00
Structural Performance (PSF)
150.00
Maximum Glazing Thickness
1.50
CRF
Not Yet Tested
U-Value
0.39
True Muntins
Yes
Interior Muntins
Yes
Historical Muntins
Yes
Blinds/Dual Glazing
Yes
Impact
No
Blast
No
2200 (NSL) Series Gallery Here
2200-nsl Series Detail Drawings PDF DWG
2200-nsl Series Specifications DOC PDF
Accessories PDF DWG
Finish Options Finishes
Order a Sample Request Here