Series B460XT Front-Set Thermal Aluminum Storefront System
Boyd's Series B460XT is the industry's first dual pour-and-debridge thermal barrier front-set commercial aluminum storefront glazing system, delivering unmatched thermal performance. The ASTM-tested system has a 2" sightline, 4.5" frame depth, and 1" maximum glazing capacity, while its front-set glass plane creates a curtain-wall aesthetic for a seamless, consistent exterior appearance.
Series B460XT is ideal for high-performance storefronts, new construction, storefront replacement, adaptive reuse, and cost-effective historic renovations. It is compatible with Boyd historic grids and offers outside-glazed, inside-glazed, and structural silicone glazed (SSG) options; screw-spline or shear-block construction; Series SV100 zero-sightline vent compatibility; heavy-duty, corner, and variable mullions; anodized and painted finishes; and seamless integration with Boyd commercial aluminum entrance systems.
Boyd maintains a full inventory of storefront-system accessories, allowing the team to prepare, package, and ship orders anywhere in the United States while cutting normal delivery times in half. A Boyd storefront representative can help coordinate B460XT framing, glazing method, historic grids, muntins, vents, entrances, mullions, finishes, accessories, drawings, specifications, and installation requirements. To discuss the project or order storefront accessories, call 800.737.2800.
Series B460XT Storefront Product Details
Series B460XT front-set framing, thermal-barrier construction, dimensions, glazing options, compatibility, and published ASTM performance:
| Product Attribute | Series B460XT Storefront System |
|---|---|
| Series | B460XT |
| Window type | Storefront |
| System type | XT dual-thermal commercial aluminum storefront framing system |
| Thermal barrier | Dual pour and debridge |
| Glass plane | Front-set storefront framing |
| Sightline | 2" |
| Main frame depth | 4.5" |
| Testing standards method | ASTM |
| Air infiltration | 0.06 @ 6.2 psf |
| Water resistance | 12.00 psf |
| Structural performance | 25.00 psf |
| Maximum glazing thickness | 1.00" |
| Glazing options | Outside glazed, inside glazed, and structural silicone glazed (SSG) |
| Fabrication options | Screw-spline or shear-block construction |
| Historic-grid compatibility | Compatible with Boyd historic grids |
| Vent compatibility | Available with Series SV100 zero-sightline vents |
| Mullion options | Heavy-duty, corner, variable, three-way, and four-way mullion configurations are available |
| Storefront entrances | Compatible with Boyd commercial aluminum entrance systems |
| Finish options | Anodized and painted finishes are available |
| Storefront accessories | Available from Boyd's maintained accessory inventory |
| Primary applications | High-performance storefront, new construction, storefront replacement, historic renovation, adaptive reuse, and commercial projects requiring front-set XT thermal framing with a curtain-wall aesthetic |
Series B460XT Product Data and Downloads
Use the current Boyd resources below for B460XT detail drawings, product specifications, installation support, XT storefront comparison, historic grids and muntins, zero-sightline vents, thermal entrance doors, accessories, and finish coordination.
| Resource | Available Files or Project Resource |
|---|---|
| Series B460XT Detail Drawings | PDF | DWG |
| Series B460XT Product Specifications | DOC |
| Series B460XT Installation Instructions | Available through Boyd project support |
| XT High-Performance Thermal Storefront Systems | Compare B460XT, B450XT, D350XT, and D500XT systems |
| Storefront and Curtain-Wall Applied Architectural Muntins | Review historic grids and applied muntin systems |
| Series SV100 Zero-Sightline Vents | Review compatible storefront ventilation |
| Commercial Aluminum Storefront Doors | Review compatible thermal entrance doors |
| Storefront Accessories | Review storefront and perimeter accessories |
| Boyd Finish Options | Review anodized and painted finishes |
When to Use the Series B460XT Storefront System
Commercial storefront projects requiring XT high-performance aluminum framing with a dual pour-and-debridge thermal barrier.
Low-rise, ground-level, single-story glazed openings requiring a front-set glass plane, 2" sightline, 4.5" frame depth, and glazing up to 1" thick.
Projects requiring a front-set glass plane that mimics curtain wall and creates a seamless, consistent exterior appearance.
New construction, storefront replacement, adaptive reuse, and energy-conscious building-envelope projects requiring coordinated thermal storefront framing and entrance systems.
Cost-effective historic renovations requiring compatibility with Boyd historic grids, applied muntins, finish coordination, and a front-set storefront profile.
Projects requiring outside-glazed, inside-glazed, or structural silicone glazed storefront details.
Projects requiring screw-spline or shear-block construction and heavy-duty, corner, variable, three-way, or four-way mullion configurations.
Storefront elevations requiring compatible Series SV100 zero-sightline awning or casement project-out vents.
Storefront entrance packages requiring coordination with Boyd D350XT medium-stile or D500XT wide-stile thermally broken entrance doors.
Storefront and accessory orders where Boyd's maintained inventory, careful packaging, nationwide shipping, and reduced normal delivery time support the project schedule.
Choosing an XT or Standard Boyd Storefront System
You are viewing the B460XT front-set system in Boyd's XT high-performance thermal storefront line. Storefront selection should begin with the required thermal strategy, front-set or center-set glass plane, glazing method, frame dimensions, glazing thickness, historic-grid requirements, entrance type, ventilation, mullion configuration, finish, water management, wind load, and opening conditions. Review the related systems below when the project requires center-set XT framing, standard thermal storefront framing, non-thermal framing, a dedicated historic-replica profile, zero-sightline ventilation, or coordinated XT thermal entrance doors.
| Series | Review This Storefront, Vent, or Entrance Option For |
|---|---|
| Series B460XT | Current system: XT dual-thermal front-set storefront framing with a 2" sightline, 4.5" frame depth, 1" maximum glazing, outside-glazed, inside-glazed, and SSG options, historic-grid compatibility, SV100 vent compatibility, heavy-duty mullions, and Boyd entrance integration. |
| Series B450XT | XT dual-thermal center-set storefront framing when the project requires a center-set glass plane, historic-grid compatibility, screw-spline or shear-block construction, SV100 vent coordination, heavier mullions, and Boyd entrance integration. |
| Series B450 | Standard thermally broken center-set storefront framing when the project requires a thermal barrier, a 2" × 4.5" profile, glazing up to 1", entrances, vents, and accessories without the XT front-set configuration. |
| Series B450N | Non-thermal 2" × 4.5" storefront framing when the project requires glazing up to 1" but does not require a thermal barrier. |
| Series BH01 | Historic-replica storefront framing when decorative wood-storefront sightlines, 2.5" or 7" horizontals, large glass lites, and a dedicated historic-storefront profile are required. |
| Series SV100 | Thermally broken zero-sightline ventilation for compatible storefront and curtain-wall conditions requiring awning or casement project-out operation with minimal visual interruption. |
| Series D350XT | Thermally broken medium-stile entrance doors when the storefront entrance requires a 3.5" stile, 2" door thickness, 1" glazing, and coordinated thermal framing. |
| Series D500XT | Thermally broken wide-stile entrance doors when the storefront entrance requires a 5" stile, 2" door thickness, 1" glazing, and a broader thermal door profile. |
Series B460XT Storefront System Advantages
The industry's first dual pour-and-debridge thermal barrier front-set storefront glazing system.
Front-set glass plane mimics curtain wall for a seamless, consistent exterior appearance.
Delivers unmatched thermal performance and superior thermal values for high-performance commercial storefront projects.
A 2" sightline and 4.5" frame depth accommodate glazing up to 1" thick.
Published ASTM performance includes 0.06 air infiltration at 6.2 psf, 12.00 psf water resistance, and 25.00 psf structural performance.
Outside-glazed, inside-glazed, and structural silicone glazed options support varied appearance, access, and installation requirements.
Compatible with Boyd historic grids for cost-effective historic renovations, adaptive reuse, restoration, and storefront replacement.
Screw-spline or shear-block construction supports varied fabrication and field-assembly plans.
Heavy-duty, corner, variable, three-way, and four-way mullion configurations support storefront layout and architectural flexibility.
Compatible with Series SV100 thermally broken zero-sightline awning and casement project-out vents.
Integrates with Boyd commercial aluminum entrance systems, including D350XT medium-stile and D500XT wide-stile thermal doors.
Anodized and painted finish options support contemporary, historic, institutional, retail, and project-specific appearance requirements.
A full storefront-accessory inventory supports coordinated subsills, mullions, adaptors, anchors, trim, perimeter components, and installation needs.
Boyd representatives support system selection, glazing path, grids, muntins, storefront layouts, entrances, vents, finishes, drawings, specifications, order preparation, packaging, and installation planning.
Careful packaging and nationwide shipping can cut normal delivery times in half.
Common Series B460XT Storefront Coordination Items
Thermal strategy: Coordinate the dual pour-and-debridge thermal barrier with the glazing package, thermal entrance doors, adjacent wall conditions, energy-code criteria, condensation requirements, U-factor or U-value targets, SHGC requirements, and perimeter details.
Front-set glass plane: Confirm that the front-set B460XT appearance and glazing position match the architectural intent. Review B450XT when a center-set glass plane and traditional storefront appearance are required.
Storefront versus curtain wall: B460XT creates a curtain-wall aesthetic but remains a storefront framing system. When an elevation spans multiple stories, crosses floor lines, or requires curtain-wall anchorage and movement accommodation, review a curtain-wall system instead.
Glazing method: Select outside-glazed, inside-glazed, or structural silicone glazed details and coordinate glass access, installation sequence, sealants, gaskets, stops, structural silicone requirements, inspection, replacement glazing, and adjacent conditions.
Glazing makeup: Confirm the complete glass makeup, 1-inch maximum thickness, safety glazing, coatings, tint, heat treatment, spacers, edge conditions, setting blocks, glass availability, thermal targets, and glazing responsibility.
Fabrication and shop drawings: Select screw-spline or shear-block construction and coordinate extrusions, fasteners, shear blocks, drill requirements, cut lists, shop drawings, frame assembly, opening identification, and field installation sequence.
Historic grids and muntins: Confirm the grid pattern, lite divisions, muntin profile, dimensions, attachment, joints, finish, glass replacement strategy, prefabrication scope, field installation, alignment across frames, and coordination with entrance doors.
SV100 vent integration: Confirm awning or casement project-out operation, vent dimensions, surrounding glazing pocket, screens, operating hardware, interior and exterior clearance, drainage, flashing, finish, and installation details.
Mullions and spans: Coordinate opening width and height, vertical- and horizontal-mullion spacing, heavy-duty, corner, variable, three-way, or four-way configurations, wind pressure, glass weight, dead load, reinforcement, expansion, anchors, and intermediate horizontals.
Air, water, and structural performance: Coordinate 0.06 air infiltration at 6.2 psf, 12.00 psf water resistance, and 25.00 psf structural performance with opening dimensions, mullion spacing, reinforcement, glazing, anchorage, and installation conditions.
Entrance integration: Coordinate D350XT or D500XT door selection, entrance frames, single doors or pairs, sidelites, transoms, thresholds, panic hardware, closers, access control, clear openings, accessibility, 1-inch glazing, thermal continuity, and finish.
Water management: Coordinate subsill, end dams, sill flashing, weep paths, glazing pockets, perimeter sealants, backer materials, thresholds, adjacent construction, and field drainage conditions.
Anchoring and perimeter conditions: Verify rough openings, field dimensions, substrates, anchors, fasteners, shims, perimeter joints, sealants, dissimilar-material isolation, trims, adaptors, and accessory scope against approved shop drawings.
Finish and protection: Coordinate anodized or painted finish, color samples, grids, muntins, entrance hardware, vents, accessories, exposed fasteners, adjacent materials, jobsite protection, cleaning, and touch-up requirements.
Inventory, shipping, and installation sequence: Provide storefront and accessory quantities, required delivery date, opening priorities, packaging or sorting needs, site access, storage plan, fabrication responsibility, and installation sequence when shorter delivery times are needed.
What to Send Boyd for a Series B460XT Storefront Review
Send as much of the following project information as available:
Project name, location, bid deadline, required response date, construction schedule, installation dates, and project contacts.
Architectural drawings, elevations, storefront schedules, door schedules, vent schedules, hardware schedules, specifications, Division 08 requirements, and opening dimensions.
Confirmation that B460XT front-set XT thermal storefront framing is required, including the 2-inch sightline, 4.5-inch frame depth, dual pour-and-debridge thermal barrier, screw-spline or shear-block construction, and installation responsibility.
Required glazing path: outside glazed, inside glazed, or structural silicone glazed, including glass installation access, silicone requirements, gaskets, stops, sealants, inspection, and replacement-glazing strategy.
Glass makeup, glazing thickness up to 1 inch, safety glazing, coatings, tint, heat treatment, spacers, setting blocks, glass availability, and glazing responsibility.
Thermal requirements including U-factor or U-value target, SHGC target if specified, energy-code criteria, condensation requirements, entrance thermal strategy, perimeter conditions, and adjacent-wall construction.
Design pressures, 0.06 air infiltration at 6.2 psf, 12.00 psf water resistance, 25.00 psf structural performance, mullion spacing, heavy-duty or specialty mullions, reinforcement, expansion, anchorage, and project-engineer requirements.
Historic-grid or muntin pattern, lite divisions, profile, dimensions, attachment, joints, finish, prefabrication scope, field-installation requirements, and alignment across storefront frames and entrances.
Series SV100 vent requirements including awning or casement project-out operation, dimensions, screens, hardware, glazing, sightline, thermal criteria, drainage, clearance, and installation details.
Thermal entrance requirements including D350XT or D500XT selection, single doors or pairs, sidelites, transoms, thresholds, rails, panic hardware, closers, access control, accessibility, clear openings, glazing, and finish.
Subsill, end-dam, sill-flashing, weep, perimeter-sealant, backer, anchor, fastener, substrate, adaptor, trim, and adjacent-construction details.
Anodized or painted finish, color, samples, grid and muntin finish, entrance finish, vent finish, accessory finish, exposed-fastener requirements, and adjacent-material coordination.
Order quantities, extrusion or fabricated-frame scope, accessory package, delivery address, required delivery date, packaging, opening-by-opening sorting, site access, storage, and installation sequencing needs.
Related XT Storefront, Entrance, Vent, and Architectural Resources
XT high-performance thermal storefront systems for B460XT front-set, B450XT center-set, D350XT medium-stile, and D500XT wide-stile thermal system comparison.
Commercial aluminum storefront systems for non-thermal, standard thermal, XT dual-thermal, historic-replica, and vent selection guidance.
Commercial aluminum storefront doors and entrance systems for XT thermal and standard narrow-, medium-, and wide-stile entrance coordination.
Storefront and curtain-wall applied architectural muntins for historic-grid, divided-lite, simulated-steel, and custom muntin coordination.
Series SV100 Zero-Sightline Vents for compatible thermally broken awning and casement project-out ventilation.
Commercial storefront and window accessories for subsills, mullions, adaptors, anchors, trim, perimeter components, and installation coordination.
Commercial curtain-wall systems for elevations extending beyond typical storefront height, anchorage, movement, or multi-story conditions.
Historic-replica and steel-replica systems for storefront replacement, adaptive reuse, historic-grid, profile, finish, and reviewing-authority coordination.
Commercial aluminum finish options for anodized, painted, custom-color, storefront, entrance, vent, grid, muntin, and accessory finishes.
Architectural resources, CAD details, product specifications, and project support for B460XT documentation and coordination.
B460XT Detail Drawings PDF DWG
B460XT Specifications DOC
B460XT Installation Instructions
Finish Options Finishes
Order a Sample Request Here