Series 3250XTP-G Historic-Replica Aluminum Project-In Windows
Boyd's Series 3250XTP-G Project-In is a historic-replica commercial aluminum thermal-strut window designed to save energy, minimize condensation potential, and deliver high performance over the life of the building. This inward-opening projected-window system combines an impressive 39mm polyamide thermal strut, a 3.25" main frame depth, a tank sill for increased water performance, and exterior snap-in muntins in a sleek historic replica designed to pass meticulous historic review.
Engineered to AW-PG80 projected-window requirements, the Series 3250XTP-G Project-In features .125" structural wall areas, a flush appearance when closed, mitered and corner-keyed sash construction, interior snap-in glazing, 1" or 1.75" glass configurations, and a .5" glass bite. Four-bar friction-hinge and operator options, two rows of weatherstripping, screens, true and simulated muntins, internal blinds or dual glazing, coordinated perimeter accessories, and blast-resistant configurations support demanding historic-replica, restoration, adaptive-reuse, and energy-conscious replacement projects.
Series 3250XTP-G Project-In Product Details
Key historic-replica project-in window attributes for product review:
| Product Attribute | Series 3250XTP-G Project-In |
|---|---|
| Window type | Historic-replica commercial aluminum project-in projected window |
| Operation | Inward-opening projected operation; this is a projected-window configuration, not a side-hinged casement |
| Primary applications | Historic-replica, restoration, adaptive-reuse, energy-conscious replacement, institutional, and other demanding commercial projects |
| Thermal barrier | 39mm extra-wide 6/6 polyamide crimped-in-place structural thermal strut |
| Main frame depth | 3.25" |
| Sill construction | Tank sill for increased water performance |
| Structural wall thickness | Structural wall areas are nominally .125" thick for durability |
| Sash construction | Mitered, corner keyed, and crimped sash for increased strength |
| Main-frame construction | Square-cut and mechanically fastened |
| Operating hardware | Four-bar stainless steel friction hinges; available hardware packages include lever-and-cam latch, custodial cam latch, telescoping push-bar, or gear-type rotary operator configurations |
| Weatherstripping | Two rows of TPE weatherstripping at sash members |
| Maximum glazing thickness | 1.75" |
| Glazing options | 1" and 1.75" insulating-glass configurations |
| Glazing method | Interior glazed with snap-in glazing beads and a .5" glass bite |
| Performance class | AW-PG80 |
| Testing standard | AAMA/WDMA/CSA 101/I.S.2/A440-08 |
| Air infiltration | 0.06 cfm/ft² at 6.2 psf |
| Water resistance | 15 psf in the current product table; confirm the applicable 12.11 or 15.04 psf guide-specification selection for the project |
| Structural performance | 120 psf |
| Thermal performance | The standard 3250XTP Project-In product-sheet configuration lists a 0.43 U-factor using 0.24 center-of-glass U-factor under NFRC 100; confirm the project-specific 3250XTP-G historic-replica configuration |
| Historic detailing | Exterior snap-in muntins on the -G configuration |
| Muntin options | True divided-lite, interior roll-form, surface-applied, and historical muntin options |
| Blinds / dual glazing | Available |
| Screens | Available for operable vents |
| Forced-entry resistance | Performance Level 10 requirements when tested according to ASTM F588 |
| Blast capability | Blast-resistant configurations available; documentation is configuration-specific |
| Impact capability | No |
Series 3250XTP-G Product Data and Downloads
Use the current Boyd resource links below for Series 3250XTP-G Project-In drawings, guide specifications, installation instructions, accessories, thermal-performance information, historic-replica resources, and blast review.
| Resource | Available Files |
|---|---|
| 3250XTP-G Project-In Detail Drawings | PDF | DWG |
| 3250XTP-G Projected-With-Grid Guide Specifications | DOC | PDF |
| Series 3250XT Installation Instructions | |
| Series 3250XT Accessories | PDF | View accessories |
| Series 3250XT Thermal-Strut Product Sheet | |
| 3250XT and the 2030 Challenge Case Study | Read the case study |
| Blast-Resistant Configuration Review | View blast systems |
| Historic-Replica Window Resources | View historic systems |
| Boyd Finish Options | View finishes |
When to Use the Series 3250XTP-G Project-In Window
Historic-replica, restoration, adaptive-reuse, or replacement openings requiring inward-projecting operation and exterior snap-in muntins.
Energy-conscious projects seeking a 39mm thermal-strut aluminum window system designed to reduce frame heat transfer and minimize condensation potential.
Projects requiring AW-PG80 projected-window performance, a 3.25" frame, a tank sill, 15 psf published water performance, and glazing up to 1.75" thick.
Historic-review projects requiring a flush, sleek appearance, grid or muntin coordination, sash proportions, finish matching, and project-specific opening details.
Commercial openings requiring interior glazing, a .5" glass bite, true or simulated muntins, internal blinds or dual glazing, screens, and coordinated perimeter accessories.
Blast-resistant applications where the exact Series 3250XTP-G Project-In configuration, glazing, anchorage, opening size, and current supporting documentation match the project requirements.
Choosing a 3250XT Historic-Replica Project-In Configuration
You are viewing the historic-replica 3250XTP-G Project-In projected window. It opens inward but is not the same as the side-hinged 3250XTC-G casement. Review the related 3250XT configurations below when the project requires outward projection, a non-G projected window, side-hinged casement operation, or a matching fixed unit.
| Series | Review This Configuration For |
|---|---|
| Series 3250XTP-G Project-Out | Historic-replica project-out projected operation when the vent should project outward while retaining the 39mm thermal strut, 3.25" frame, exterior snap-in muntins, and AW-PG80 performance. |
| Series 3250XTP Project-In | Non-G project-in projected operation when the project requires the 3250XT thermal-strut platform without the historic-replica exterior snap-in muntin configuration. |
| Series 3250XTC-G Casement Project-In | Historic-replica inward-opening casement operation when the project requires a side-hinged sash and AW-PG100 performance rather than projected-window operation. |
| Series 3250XTF-G Fixed | Matching non-operable historic-replica openings requiring exterior snap-in muntins, 39mm thermal-strut construction, and visual coordination with operable 3250XT-G units. |
Series 3250XTP-G Project-In Window Advantages
39mm extra-wide polyamide crimped-in-place structural thermal barrier for extremely low listed U-values and improved condensation resistance.
Historic-replica appearance designed to pass meticulous historic review.
Exterior snap-in muntins for coordinated historic grid and divided-lite appearance.
Tank sill for increased water performance in the project-in configuration.
A 3.25" main frame depth with .125" structural wall areas for durability.
Flush vent appearance when closed for a sleek, visually refined historic replica.
Interior snap-in glazing accommodates 1" and 1.75" glass configurations with a .5" glass bite.
Mitered, corner keyed, and crimped sash construction for increased strength; main-frame construction is square-cut and mechanically fastened.
Four-bar friction-hinge packages can be coordinated with lever-and-cam latches, custodial cam latches, telescoping push bars, or gear-type rotary operators.
Two rows of weatherstripping support ideal air performance.
True divided-lite, interior, surface-applied, and historical muntins, internal blinds or dual glazing, and screens are available.
Panning, thermally broken receptors, subsills, caulk backers, mullions, snap trims, finishes, and project-specific customization support complex opening conditions.
Performance Level 10 forced-entry requirements and configuration-specific blast-resistance capabilities support demanding commercial applications.
Common Series 3250XTP-G Project-In Coordination Items
Projected operation: Confirm that the schedule requires an inward-opening projected window rather than a side-hinged project-in casement. Coordinate hinge location, operator package, sash projection, hardware reach, opening force, and user access.
Interior clearance: Review the inward vent path against interior trim, blinds, shades, screens, furniture, casework, occupants, security devices, and maintenance access.
Historic review: Coordinate existing profiles, sightlines, sash proportions, exterior snap-in muntins, grid pattern, muntin width and depth, finish, panning, perimeter conditions, and reviewing-authority comments.
Tank sill and drainage: Coordinate sill elevation, drainage path, perimeter sealants, flashing, receptors, subsills, panning, adjacent construction, and installation details so the intended water-management approach is maintained.
Glazing and thermal performance: Confirm complete glass makeup, overall thickness, center-of-glass performance, spacer, safety glazing, coatings, interior glazing access, .5" glass bite, and project-specific U-factor or condensation criteria.
Hardware and screens: Select the required lever-and-cam latch, custodial latch, push-bar, or rotary-operator package and coordinate screen type, wickets, hardware clearances, user operation, and cleaning access.
Blast requirements: Provide the required protection level, threat criteria, glazing, opening size, anchorage, substrate, receptor, mullion, installation condition, and current documentation requirements. Blast availability is configuration-specific.
Openings and accessories: Verify field dimensions, rough openings, substrates, anchors, panning, thermally broken receptors, subsills, mullions, caulk backers, snap trims, sealants, drainage, finishes, and surrounding construction before release.
What to Send Boyd for a Series 3250XTP-G Review
Send as much of the following project information as available:
Project name, location, building type, bid date, construction schedule, architectural drawings, elevations, window schedules, specifications, and opening sizes.
Historic-review requirements, existing-window photographs or profiles, sash proportions, sightlines, exterior snap-in muntin pattern, muntin profile, finish, and reviewing-authority comments.
Confirmation that the opening requires project-in projected operation, along with hinge location, operator or latch package, vent size, inward clearance, screens, user access, and maintenance requirements.
Glazing makeup, overall thickness, center-of-glass performance, coatings, spacers, safety glazing, internal blinds or dual glazing, and required U-factor or condensation criteria.
Required AW-PG80, air, water, structural, forced-entry, blast, security, energy-code, historic-review, and jurisdictional criteria.
For blast projects, provide threat criteria, protection level, opening sizes, glazing, anchors, substrates, receptors, mullions, and installation conditions.
Tank-sill, panning, receptor, subsill, mullion, caulk-backer, snap-trim, anchor, sealant, drainage, substrate, installation, finish, and submittal requirements.
Related 3250XT, Project-In, Historic, and Blast Resources
Commercial aluminum project-in windows for projected-in and project-in casement comparison and selection guidance.
3250XT high-performance thermal-strut windows for fixed, projected, casement, standard, and historic-replica configuration review.
Historic-replica and steel-replica aluminum window systems for sightline, profile, muntin, finish, and reviewing-authority coordination.
Blast-resistant commercial aluminum window systems for configuration-specific performance and documentation review.
Commercial window accessories for panning, receptors, subsills, mullions, caulk backers, snap trims, screens, and related coordination.
Commercial aluminum finish options for standard and custom anodized or painted finish review.
Boyd Series 3250XT and the 2030 Challenge case study for an energy-conscious commercial project example.
Architectural resources, CAD details, specifications, and product support for project documentation.
3250XTP-G (PI) Series Specifications DOC PDF
3250XTP Installation Instructions PDF
Accessories PDF DWG
Product Sheet PDF
Finish Options Finishes
Order a Sample Request Here