Series 3250XTP Aluminum Project-Out Thermal-Strut Windows

Boyd's Series 3250XTP Project-Out is a high-performance commercial aluminum thermal-strut window with outward-projecting operation. Its industry-leading 39mm polyamide thermal strut and 3.25" main frame depth support low U-value performance for schools, universities, government offices, hospitals, military buildings, and other commercial applications that must meet stringent energy-code requirements and maximize performance over the life of the building.

Engineered to AW-PG80 projected-window requirements, the Series 3250XTP Project-Out is interior glazed with 1" or 1.75" glass, snap-in glazing beads, and a .5" glass bite. Its mitered, corner-keyed, and crimped sash provides increased strength, while .125" structural wall areas, square-cut mechanically fastened main-frame construction, two rows of weatherstripping, and pressure equalization support durability, ideal air performance, and superior water performance. The flush closed-vent appearance gives designers the clean, sleek look that is in high demand, while screens, muntins, internal blinds or dual glazing, coordinated perimeter accessories, and configuration-specific blast-resistant capabilities support demanding commercial projects.

Series 3250XTP Project-Out Product Details

Key commercial project-out thermal-strut window attributes for product review:

Product AttributeSeries 3250XTP Project-Out
Window typeCommercial aluminum project-out projected window
OperationOutward-opening projected operation; this is a projected-window configuration
Primary applicationsSchools, universities, government offices, hospitals, military buildings, energy-conscious renovations, and other commercial projects with stringent energy-code requirements
Thermal barrier39mm extra-wide 6/6 polyamide crimped-in-place structural thermal strut
Main frame depth3.25"
Water-management designPressure-equalized project-out construction for superior water performance
Structural wall thicknessStructural wall areas are nominally .125" thick for durability
Sash constructionMitered, corner keyed, and crimped sash for increased strength
Main-frame constructionSquare-cut and mechanically fastened
Operating hardwareFour-bar stainless steel friction hinges with project-specific operating hardware selected according to projection direction and current approved documentation
WeatherstrippingTwo rows of TPE weatherstripping at sash members
Maximum glazing thickness1.75"
Glazing options1" and 1.75" insulating-glass configurations
Glazing methodInterior glazed with snap-in glazing beads and a .5" glass bite
Performance classAW-PG80
Testing standardAAMA/WDMA/CSA 101/I.S.2/A440-08
Air infiltration0.06 cfm/ft² at 6.2 psf
Water resistance15 psf in the current product table and product sheet; the guide specification provides a 12.11 or 15.04 psf selection, so confirm the governing project requirement
Structural performance120 psf
Published thermal performance0.43 U-factor using 0.24 center-of-glass U-factor under NFRC 100; job-specific results vary with glass and spacer selection
Muntin optionsTrue divided-lite, interior roll-form, surface-applied, and historical muntin options; exterior snap-in muntins are associated with the -G historic-replica configuration
Blinds / dual glazingAvailable
ScreensAvailable for operable vents
Forced-entry resistancePerformance Level 10 requirements when tested according to ASTM F588
Blast capabilityBlast-resistant configurations available; documentation is configuration-specific
Impact capabilityNo

Series 3250XTP Product Data and Downloads

Use the current Boyd resource links below for Series 3250XTP Project-Out drawings, guide specifications, installation instructions, accessories, thermal-performance information, the 2030 Challenge case study, and blast review.

ResourceAvailable Files
3250XTP Project-Out Detail DrawingsPDF  |  DWG
3250XTP Projected-Window Guide SpecificationsDOC  |  PDF
Series 3250XT Installation InstructionsPDF
Series 3250XT AccessoriesPDF  |  DWG  |  View accessories
Series 3250XT Thermal-Strut Product SheetPDF
3250XT and the 2030 Challenge Case StudyRead the case study
Blast-Resistant Configuration ReviewView blast systems
Boyd Finish OptionsView finishes
Request a Bid / Project Help Get Direct Assistance™

When to Use the Series 3250XTP Project-Out Window

  • Commercial openings requiring outward-projecting operation rather than an inward-projecting vent or side-hinged casement.

  • Schools, universities, government offices, hospitals, military buildings, and other projects with stringent energy-code requirements.

  • Energy-conscious new-construction or replacement projects seeking a 39mm thermal-strut window designed to reduce frame heat transfer and support low U-value performance.

  • Projects requiring AW-PG80 projected-window performance, a 3.25" pressure-equalized frame, 15 psf published water resistance, and glazing up to 1.75" thick.

  • Openings requiring a flush closed-vent appearance, interior glazing, true or simulated muntins, internal blinds or dual glazing, screens, and coordinated perimeter accessories.

  • Blast-resistant applications where the exact Series 3250XTP Project-Out configuration, glazing, anchorage, opening size, and current supporting documentation match the project requirements.

Choosing a 3250XT Project-Out Configuration

You are viewing the standard 3250XTP Project-Out projected window. It opens outward but is not the same as the side-hinged 3250XTC casement. Review the related 3250XT configurations below when the project requires historic-replica exterior snap-in muntins, inward projection, side-hinged casement operation, or a matching fixed unit.

SeriesReview This Configuration For
Series 3250XTP-G Project-OutHistoric-replica project-out projected operation when the project requires exterior snap-in muntins and historic-review coordination while retaining the 39mm thermal strut, 3.25" frame, and AW-PG80 performance.
Series 3250XTP Project-InInward-opening projected operation when the vent should project into the building and the project requires a tank sill rather than pressure-equalized project-out construction.
Series 3250XTC Casement Project-OutOutward-opening side-hinged casement operation when the project requires AW-PG100 casement performance instead of projected-window operation.
Series 3250XTF FixedMatching non-operable thermal-strut openings requiring a 39mm thermal strut, 3.25" frame, AW-PG100 fixed-window performance, and visual coordination with operable 3250XT units.

Series 3250XTP Project-Out Window Advantages

  • Industry-leading 39mm extra-wide polyamide crimped-in-place structural thermal barrier for extremely low listed U-values.

  • Published 0.43 U-factor using 0.24 center-of-glass U-factor under NFRC 100.

  • A 3.25" main frame depth with .125" structural wall areas for durability.

  • Pressure equalization supports superior water performance in the project-out configuration.

  • The vent presents a flush appearance with the exterior and interior main-frame faces when closed for a desirable, clean look.

  • Interior snap-in glazing accommodates 1" and 1.75" glass configurations with a .5" glass bite.

  • Mitered, corner keyed, and crimped sash construction provides increased strength; main-frame construction is square-cut and mechanically fastened.

  • Four-bar stainless steel friction hinges are paired with project-specific operating hardware selected for the projection direction and approved documentation.

  • Two rows of weatherstripping support ideal air performance.

  • True divided-lite, interior roll-form, surface-applied, and historical muntin options, internal blinds or dual glazing, and screens are available.

  • Panning, thermally broken receptors, subsills, caulk backers, mullions, snap trims, finishes, and project-specific customization support complex opening conditions.

  • Performance Level 10 forced-entry requirements and configuration-specific blast-resistant capabilities support demanding commercial applications.

Common Series 3250XTP Project-Out Coordination Items

  • Projected-out operation: Confirm that the schedule requires an outward-opening projected window rather than a side-hinged project-out casement. Coordinate hinge location, operating-hardware package, sash projection, opening force, user access, and ventilation strategy.

  • Exterior clearance: Review the outward projection path against walkways, railings, sunshades, screens, louvers, security conditions, adjacent walls, maintenance access, and other exterior obstructions.

  • Pressure equalization and drainage: Coordinate sill details, drainage paths, perimeter sealants, flashing, receptors, subsills, panning, adjacent construction, and installation details so the intended water-management approach is maintained.

  • Glazing and thermal performance: Confirm complete glass makeup, overall thickness, center-of-glass performance, spacer, safety glazing, coatings, interior glazing access, .5" glass bite, and project-specific U-factor or condensation criteria.

  • Muntins and appearance: Coordinate true divided-lite, interior roll-form, surface-applied, or historical muntin construction, grid pattern, profile, finish, and reglazing requirements. Use the -G configuration when exterior snap-in muntins are required.

  • Hardware and screens: Confirm the project-specific operating hardware permitted for project-out use, along with four-bar hinges, screen type, wickets, hardware clearances, user operation, and cleaning access.

  • Performance documentation: The live product page and product sheet list AW-PG80, 120 psf structural performance, and 15 psf water resistance. The shared guide specification contains editable performance selections and an internal AW-PG100 reference, so confirm the current certified test report and approved project documentation.

  • Blast requirements: Provide the required protection level, threat criteria, glazing, opening size, anchorage, substrate, receptor, mullion, installation condition, and current documentation requirements. Blast availability is configuration-specific.

  • Openings and accessories: Verify field dimensions, rough openings, substrates, anchors, panning, thermally broken receptors, subsills, mullions, caulk backers, snap trims, sealants, drainage, finishes, and surrounding construction before release.

What to Send Boyd for a Series 3250XTP Review

Send as much of the following project information as available:

  • Project name, location, building type, bid date, construction schedule, architectural drawings, elevations, window schedules, specifications, and opening sizes.

  • Confirmation that the opening requires project-out projected operation, along with hinge location, approved operating-hardware package, vent size, exterior clearance, screens, user access, and maintenance requirements.

  • Glazing makeup, overall thickness, center-of-glass performance, coatings, spacers, safety glazing, internal blinds or dual glazing, muntin construction, grid pattern, and required U-factor or condensation criteria.

  • Required AW-PG80, air, water, structural, forced-entry, blast, security, energy-code, and jurisdictional criteria.

  • For blast projects, provide threat criteria, protection level, opening sizes, glazing, anchors, substrates, receptors, mullions, and installation conditions.

  • Pressure-equalization, panning, receptor, subsill, mullion, caulk-backer, snap-trim, anchor, sealant, drainage, substrate, installation, finish, and submittal requirements.

Related 3250XT, Project-Out, Thermal, and Blast Resources

Request a Bid / Project Help Get Direct Assistance
Series
3250XT
Window Type
Project-Out
Thermal Barrier
Thermal Strut
System Depth (Inches)
3.25
AAMA Rating
AW-PG80
Testing Standards Method
2008
Air Infiltration (CFM/FT)
.06 @ 6.2
Water Resistance (PSF)
15.00
Structural Performance (PSF)
120.00
Maximum Glazing Thickness
1.75
U-Value
See Chart
True Muntins
Yes
Interior Muntins
Surface Applied
Historical Muntins
Yes
Blinds/Dual Glazing
Yes
Blast
Yes
Impact
No
3250XTP (PO) Series Detail Drawings PDF DWG
3250XTP (PO) Series Specifications DOC PDF
3250XTP Installation Instructions PDF
Accessories PDF DWG
Product Sheet PDF
Finish Options Finishes