Series 3250XTC Aluminum Casement Project-In Windows

The Boyd Series 3250XTC (PI) is a commercial aluminum thermal-strut casement window that opens inward and delivers unparalleled energy efficiency with a sleek, modern appearance. Its industry-leading 39mm structural polyamide thermal strut, 3.25" main frame depth, and tank sill support commercial projects driven by the need to save energy, reduce condensation, improve water performance, and deliver proven performance over the life of the building.

The Series 3250XTC (PI) is interior glazed with 1" or 1.75" glazing, snap-in glazing beads, and a .5" glass bite. Its .125" structural wall areas and mitered, corner-keyed, and crimped sash provide increased strength, while the vent sits flush with the exterior and interior faces of the main frame when closed for a desirable, clean look. The system is AAMA tested to AW-PG100 and is available with screens, blinds or dual glazing, coordinated accessories, and blast-resistant configurations where supported by current project-specific documentation.

Series 3250XTC Project-In Product Details

Key commercial casement-window attributes for product review:

Product AttributeSeries 3250XTC (PI)
Window typeCommercial aluminum thermal-strut casement window
OperationSide-hinged project-in operation
Thermal barrier39mm 6/6 polyamide structural thermal strut
Sill configurationTank sill for increased water performance
Main frame depth3.25"
Structural wall areas.125" thick at main-frame and sash members
Glazing1" and 1.75"; maximum glazing thickness 1.75"
Glass bite.5"
Glazing methodInterior glazed with snap-in glazing bead
Closed appearanceVent sits flush with the exterior and interior faces of the main frame
Performance classAW-PG100
Testing standardAAMA/WDMA/CSA 101/I.S.2/A440-08
Air infiltration0.06 cfm/ft at 6.2 psf
Water resistance15 psf
Structural performance150 psf
Published U-factor0.43 based on 0.24 center-of-glass U-factor per NFRC 100; job-specific results vary by glazing, spacer, opening conditions, and project requirements
Muntin optionsTrue, surface-applied interior, and historical muntins
ScreensAvailable
Blinds / dual glazingAvailable
Forced-entry resistanceASTM F 588, Type D, Grade 10
Blast capabilityBlast-resistant configurations available; documentation is configuration-specific.
Impact capabilityNo

Series 3250XTC Project-In Product Data and Downloads

Use the current Boyd resource links below for Series 3250XTC Project-In drawings, guide specifications, installation guidance, accessories, thermal product data, and related project review.

ResourceAvailable Files
3250XTC Project-In Detail DrawingsPDF  |  DWG
3250XTC Casement Guide SpecificationsDOC  |  PDF
Series 3250XT Installation InstructionsPDF
Series 3250XT AccessoriesPDF
3250XT Thermal-Strut Product SheetPDF
3250XT and the 2030 ChallengeRead case study
Blast-Resistant Configuration ReviewView blast systems
Boyd Finish OptionsView finishes
Request a Bid / Project Help Get Direct Assistance™

When to Use the Series 3250XTC Project-In Casement

  • Commercial openings requiring a side-hinged casement window that opens inward.

  • Energy-conscious projects driven by the need to save energy, reduce condensation, and meet stringent thermal-performance requirements.

  • Project-in openings where a tank sill, interior glazing access, and coordinated interior operating clearance are important.

  • Contemporary commercial designs where a flush closed-vent appearance and clean frame profile help bring the architectural vision to life.

  • Operable openings requiring AW-PG100 casement performance, glazing up to 1.75", screens, and project-specific hardware coordination.

  • Blast-resistant applications where the exact opening size, glazing, anchorage, installation method, and supporting documentation are reviewed for the selected configuration.

Choosing a Related Series 3250XT Window

You are viewing the standard Series 3250XTC Project-In casement configuration. Review the related 3250XT options below when the project requires outward casement operation, projected rather than casement operation, a fixed opening, or the historic-replica “-G” version of this project-in casement.

SeriesReview This Configuration For
Series 3250XTC Casement Project-OutCasement openings requiring outward operation and exterior-clearance coordination.
Series 3250XTP Projection
Project-In
Project-Out 
Operable openings requiring projected operation rather than side-hinged casement operation.
Series 3250XTF FixedNon-operable thermal-strut openings requiring visual coordination with the operable Series 3250XT units.
Series 3250XTC-G Casement Project-InProject-in casement openings requiring the historic-replica “-G” configuration and exterior snap-in muntins.

Series 3250XTC Project-In Advantages

  • Industry-leading 39mm extra-wide polyamide structural thermal strut supports extremely low U-values and stringent energy-code goals.

  • Tank sill supports increased water performance for the inward-opening configuration.

  • Flush closed-vent appearance creates a desirable, clean modern look at both the exterior and interior faces of the main frame.

  • .125" structural wall areas and mitered, corner-keyed, and crimped sash construction provide increased strength.

  • Two rows of weather stripping support ideal air performance.

  • Interior glazing, snap-in glazing beads, .5" glass bite, and 1" or 1.75" glazing provide specification flexibility.

  • Available with screens, blinds or dual glazing, panning, receptors, caulk backers, mullions, and snap trims.

  • Complies with Performance Level 10 forced-entry requirements.

  • Blast-resistant configurations are available, with final performance documentation matched to the selected assembly and project criteria.

Common Series 3250XTC Project-In Coordination Items

  • Project-in operation: Confirm interior clearance, hardware, opening angle, screens, shades, furnishings, wall conditions, and other interior obstructions.

  • Tank sill and water management: Coordinate sill conditions, drainage, perimeter sealants, receptors, subsills, surrounding construction, and installation details.

  • Glazing: Confirm glass makeup, overall thickness, .5" glass bite, safety-glazing requirements, interior-glazing access, blinds, and dual-glazing requirements.

  • Thermal performance: Provide the project U-factor, condensation, energy-code, center-of-glass, spacer, and whole-window requirements so the selected configuration and glazing can be reviewed together.

  • Fixed and operable coordination: Coordinate sightlines, frame depth, glazing, finish, mullions, and visual alignment with adjacent Series 3250XTF fixed or 3250XTP projected windows.

  • Blast requirements: Match the exact window size, glazing, anchorage, substrate, receptor, mullion, installation method, and protection criteria to current configuration-specific documentation.

  • Openings and accessories: Verify field dimensions, rough openings, substrates, panning, receptors, caulk backers, mullions, snap trims, anchors, sealants, and surrounding construction before release.

What to Send Boyd for a Series 3250XTC Project-In Review

Send as much of the following project information as available:

  • Project name, location, bid date, and construction schedule.

  • Architectural drawings, elevations, window schedules, opening sizes, specifications, and existing-condition photographs or field measurements.

  • Project-in casement operation, hardware, screen, interior-clearance, opening-angle, and accessibility requirements.

  • Required glazing makeup, glass thickness, muntins, blinds, dual glazing, finish, and fixed-to-operable coordination.

  • Required U-factor, condensation, air, water, structural, forced-entry, and energy-code criteria.

  • Blast criteria, glazing, anchorage, substrate, panning, receptor, mullion, trim, sealant, and installation requirements where applicable.

Related Casement and Thermal Window Resources

Request a Bid / Project Help Get Direct Assistance
Series
3250XT
Window Type
Project-In
Thermal Barrier
Thermal Strut
System Depth (Inches)
3.25
AAMA Rating
AW-PG100
Testing Standards Method
2008
Air Infiltration (CFM/FT)
.06 @ 6.2
Water Resistance (PSF)
15.00
Structural Performance (PSF)
150.00
Maximum Glazing Thickness
1.75
U-Value
See Chart
True Muntins
Yes
Interior Muntins
Surface Applied
Historical Muntins
Yes
Blinds/Dual Glazing
Yes
Blast
Yes
Impact
No
3250XTC (PI) Series Detail Drawings PDF DWG
3250XTC (PI) Series Specifications DOC PDF
3250XTP Installation Instructions PDF
Accessories PDF DWG
Product Sheet PDF
Finish Options Finishes
Order a Sample Request Here