Series 4300 Aluminum Project-Out Windows
Boyd's high-performance Series 4300 is a commercial aluminum project-out window that provides a modern solution for contemporary architecture. Clean sightlines and outward-projecting operation complement new construction for colleges, schools, offices, government buildings, hospitals, military facilities, and other demanding commercial or institutional applications.
Tested to AW-PG100, the thermally broken Series 4300 features a 4" main frame, dual corner-key construction, inside- or outside-set glazing up to 1.5" thick, and 15 psf water resistance for powerful weather and coastal conditions. Stainless-steel four-bar friction hinges can be coordinated with standard, custodial, telescoping push-bar, or rotary operating hardware, while true divided-lite, interior, and historical muntins, blinds or dual glazing, removable screens, perimeter accessories, finish selections, and custom options support contemporary new-construction and replacement requirements. Impact-rated Series 4300 Project-Out configurations are available where supported by current approval documentation.
Series 4300 Project-Out Product Details
Key commercial project-out window attributes for product review:
| Product Attribute | Series 4300 Project-Out |
|---|---|
| Window type | Commercial aluminum project-out projected window |
| Operation | Outward-opening projected operation; this is a projected-window configuration |
| Primary applications | Contemporary new construction, colleges, schools, offices, government buildings, hospitals, military facilities, coastal-weather projects, and other demanding commercial applications |
| Architectural appearance | Clean sightlines and a modern projected-window profile |
| Thermal barrier | Integral urethane thermal barrier |
| Main frame depth | 4" |
| Frame construction | Dual corner-key construction |
| Aluminum wall thickness | The live product page describes .062" and .135" aluminum walls. The current guide specification lists nominal .062" main-frame walls, .125" sash walls, and .050" minimum glazing stops. Confirm the governing approved details before release. |
| Operating hardware | Stainless-steel four-bar friction hinges with lever-and-cam, custodial cam-latch, telescoping push-bar, or gear-type rotary-operator packages |
| Weatherstripping | Two rows of TPE weatherstripping at all sash members |
| Maximum glazing thickness | 1.5" |
| Glazing configuration | Inside- or outside-set glazing |
| Glazing gaskets | Sliding-type TPE gaskets at glazing stops |
| Performance class | AW-PG100 |
| Testing standard | AAMA/WDMA/CSA 101/I.S.2/A440-08 |
| Air infiltration | 0.07 cfm/ft of sash crack at 6.24 psf |
| Water resistance | No uncontrolled leakage at 15 psf |
| Structural performance | 150 psf |
| Condensation resistance factor | 55 |
| Published U-value | 0.61 |
| Muntin options | True divided-lite, interior roll-form, and applied historical or simulated muntins |
| Blinds / dual glazing | Available |
| Screens | Tight-fitting removable insect screens are available for each operable sash; wickets can be coordinated where required for hardware access |
| Forced-entry resistance | ASTM F588, Performance Level 10 |
| Impact capability | Impact-rated configurations available; approval documentation is configuration-specific. |
| Blast capability | No |
Series 4300 Product Data and Downloads
Use the current Boyd resource links below for Series 4300 Project-Out drawings, guide specifications, accessories, gallery images, and finish options.
| Resource | Available Files |
|---|---|
| Series 4300 Project-Out Detail Drawings | PDF | DWG |
| Series 4300 Project-Out Guide Specifications | DOC | PDF |
| Window Accessories | PDF | View accessories |
| Series 4300 Gallery | View gallery |
| Boyd Finish Options | View finishes |
When to Use the Series 4300 Project-Out Window
Contemporary new-construction openings requiring outward-projecting operation, clean sightlines, and a modern commercial-window appearance.
Colleges, schools, offices, government buildings, hospitals, military facilities, and other commercial or institutional applications.
Projects requiring AW-PG100 performance, a 4" thermal-break frame, 15 psf water resistance, 150 psf structural performance, and glazing up to 1.5" thick.
Coastal-weather and impact-related projects where the selected Series 4300 Project-Out configuration, glazing, size, anchorage, installation conditions, and approval documentation meet the project criteria.
Openings requiring inside- or outside-set glazing, true or simulated muntins, blinds or dual glazing, removable screens, multiple operating-hardware packages, perimeter accessories, finish options, and customization.
Projects requiring a projected-out window rather than a side-hinged casement or inward-opening projected unit.
Choosing a Boyd Project-Out Window
You are viewing the Series 4300 outward-opening projected window. It is not a side-hinged casement. Impact-rated configurations are available, while blast capability is not listed for this product. Review the related Boyd systems below when the project requires inward projection, a shallower frame, narrow sightlines, 39mm thermal-strut construction, side-hinged casement operation, or a matching fixed unit.
| Series | Review This Configuration For |
|---|---|
| Series 4300 Project-In | Inward-opening projected operation when the vent should project into the building while retaining the 4" thermal-break frame, AW-PG100 performance, and glazing up to 1.5". |
| Series 2300 Project-Out | Versatile project-out applications in a shallower 2.375" thermal-break frame with glazing up to 1.5" and selected impact- or blast-related configurations. |
| Series 2300 NSL Project-Out | Narrow-sightline project-out applications requiring a 2.375" thermal-break frame, AW-PG80 performance, and a sleeker contemporary profile. |
| Series 3250XTP Project-Out | High-performance thermal-strut project-out applications requiring a 39mm thermal strut, 3.25" pressure-equalized frame, interior glazing, and glass up to 1.75". |
| Series 4400 Casement Project-Out | Side-hinged outward-opening casement operation when the project requires a casement instead of a projected-window configuration. |
| Series 4000 Fixed | Matching non-operable openings requiring a 4" thermal-break frame, AW-PG100 performance, and coordinated glazing, muntins, finishes, and sightlines. |
Series 4300 Project-Out Window Advantages
High-performance projected-out design provides a modern window solution for contemporary architecture.
Clean sightlines complement colleges, schools, offices, government buildings, hospitals, military facilities, and other new-construction applications.
AW-PG100 performance with 15 psf water resistance and 150 psf structural performance.
A 4" thermally broken main frame accommodates inside- or outside-set glazing up to 1.5" thick.
Dual corner-key construction supports demanding commercial, institutional, and coastal-weather conditions.
Stainless-steel four-bar friction hinges can be coordinated with lever-and-cam, custodial, telescoping push-bar, or rotary operating hardware.
Two rows of TPE weatherstripping at all sash members support dependable air and water performance.
True divided-lite, interior roll-form, and applied historical or simulated muntins support contemporary, traditional, and restoration designs.
Blinds or dual glazing and tight-fitting removable screens expand project flexibility.
Panning, nailing fins, leg extenders, receptors, subsills, mullions, trims, finishes, and custom options support varied opening and installation conditions.
Published CRF 55 and U-value 0.61 provide current thermal-performance references for the standard product configuration.
Common Series 4300 Project-Out Coordination Items
Projected-out operation: Confirm that the documents require an outward-opening projected window rather than a side-hinged project-out casement. Coordinate hinge location, opening angle, operating-hardware package, hardware reach, opening force, user access, and ventilation strategy.
Exterior clearance: Review the outward projection path against walkways, railings, sunshades, screens, louvers, adjacent walls, security conditions, maintenance access, and other exterior obstructions.
Coastal, impact, and powerful-weather requirements: Coordinate design pressures, water resistance, impact criteria, approval documentation, glazing, corrosion exposure, finish, adjacent metals, drainage, flashing, sealants, anchors, substrates, and installation conditions for the selected configuration.
Glazing-set direction: Confirm inside- or outside-set glazing, complete glass makeup, overall thickness, safety glazing, glazing access, blinds or dual glazing, coatings, spacers, and required CRF or U-value.
Muntins and appearance: Coordinate true divided-lite, interior roll-form, or applied historical muntins, grid pattern, lite divisions, profile, attachment method, finish, reglazing requirements, and any restoration criteria.
Hardware and screens: Select the lever-and-cam, custodial, telescoping push-bar, or rotary hardware package and coordinate friction hinges, screens, wickets, accessibility, security, cleaning, and maintenance requirements.
Member thickness: The live product copy and current guide specification list different sash-wall values. Confirm the governing drawings, certified test information, approved specification, and current product documentation before submittal or release.
Openings and accessories: Verify field dimensions, rough openings, substrates, anchors, panning, nailing fins, leg extenders, receptors, subsills, mullions, trims, sealants, drainage, finishes, and surrounding construction before release.
What to Send Boyd for a Series 4300 Review
Send as much of the following project information as available:
Project name, location, building type, bid date, construction schedule, architectural drawings, elevations, window schedules, specifications, and opening sizes.
Confirmation that the opening requires project-out projected operation, along with opening angle, operating-hardware package, vent size, exterior clearance, screens, wickets, user access, and maintenance requirements.
Required coastal-weather and impact criteria, applicable approval documentation, design pressures, water resistance, corrosion exposure, finish, glazing, anchors, substrates, and installation conditions.
Inside- or outside-set glazing direction, glass makeup, overall thickness, coatings, spacers, safety glazing, blinds or dual glazing, muntin construction, grid pattern, and required CRF or U-value.
Required AW-PG100, air, water, structural, thermal, forced-entry, security, energy-code, and jurisdictional criteria.
Panning, nailing-fin, leg-extender, receptor, subsill, mullion, trim, anchor, sealant, drainage, substrate, installation, finish, and submittal requirements.
Related Project-Out, Project-In, Fixed, and Architectural Resources
Commercial aluminum project-out windows for projected, casement, thermal-strut, standard, historic, and narrow-sightline selection guidance.
Commercial aluminum project-in windows for inward-opening projected and casement configurations.
Commercial aluminum fixed windows for coordinated non-operable openings and matching elevations.
Commercial window accessories for screens, panning, nailing fins, leg extenders, receptors, subsills, mullions, trims, and related coordination.
Commercial aluminum finish options for standard and custom anodized or painted finish review.
Architectural resources, CAD details, specifications, and product support for project documentation.
4300 Series Detail Drawings PDF DWG
4300 Series Specifications DOC PDF
Accessories PDF DWG
Finish Options Finishes
Order a Sample Request Here